PREFACE: This article looks at the charging times & achieved state of charge of an AGM battery in multiple scenarios:
1- 50% SOC to 100% SOC at .2C 2- 50% SOC to 100% SOC at .4C 3- 50% SOC Charged at .2C For Exactly 1 Hour 4- 50% SOC Charged at .4C For Exactly 1 Hour 5- 50% SOC Charged at .2C For Exactly 2 Hours 6- 50% SOC Charged at .4C For Exactly 2 Hours
*DISCLAIMER: This test represents this slightly used AGM and may not be representative of a brand new AGM or a battery with more use and in a worse state of health.
DEFINITIONS:
.2C & .4C - Also called Point Two C and Point 4 C. This is just a percentage of Ah capacity in either charging or discharging current. For example .2C = 20% of Ah capacity or 20A for a 100Ah battery and .4C = 40% of Ah capacity or a 40A charge or discharge current for a 100Ah battery.
SOC - Sate of Charge
DOD - Depth of Discharge
Ah Capacity - The total ampere hours a battery can store and deliver at a discharge rate that yields a 20 hour run time at 77F before hitting a terminal voltage of 10.5V.
20 Hour Discharge Rate - Also the "20 hour rate". The discharge current at 77F that will yield a 20 hour run time before hitting 10.5V
How long does it take to charge from 50% SOC to 100% SOC?
I have long known that a higher charge rate, with AGM batteries, does not necessarily translate to *significantly faster charge times from 50% SOC to 100% SOC. For the first part of this test, 50% SOC to 100% SOC, I compared a charge rate of .2C with a charge rate of .4C on the same Lifeline GPL-31T battery.
"Significantly Faster" - Please understand, & take with a grain of salt, what I am comparing "significantly faster" to. I was once told by a self espoused expert on AGM batteries (expert defined here as an owner who had AGM batteries and whom had read the glossy marketing materials) that with his 150A alternator he could recharge his 440Ah bank of AGM batteries from 50% to 100% in less than an hour and a half. While the owner was fully capable of basic math, 1.5 hours times 150A = 225Ah's he failed to take into consideration that his .34C 150A alternator could not put out 150A for 1.5 hours and his bank, at anywhere close to .34C, would hit absorption voltage rapidly and begin limiting alternator current. Even if the alt could run at at a face value of 150A it is simply impossible to return 225Ah's to the bank in 1.5 hours from 50% SOC.
One can't really can't blame this owner for his rather misguided expertise because he had been rather grossly mislead by nearly everyone in the industry on the expected charge times from 50% SOC to 100% SOC with AGM batteries. Suffice it to say it is physically impossible to recharge a 440Ah bank of AGM batteries at 50% SOC to 100% SOC in 1.5 hours with a .34C charge current.
The actual tested capacity of the group 31 AGM battery was 95.69Ah's, its rated Ah capacity is 105Ah. For charge and discharge rates I kept them based on the "as new" capacity just as many boaters would do.
Charge Rate Explained:
0.2C = 20% Charge Rate of the Ah Capacity
0.4C = 40% Charge Rate of the Ah Capacity
In this image we have removed 48.54Ah from the battery which tested at 95.69Ah's of actual capacity. This leaves the battery at 49.3% SOC or just about 50% SOC. Voltage was used as the cut-off and 12.100V at 5.25A was the stop point for the discharge testing.
The Test Battery:
The battery used for this testing is a 2015 Lifeline Group 31 AGM Deep Cycle battery. It had been used for approx 5 months as part of a bank on a power boat (trawler type) that cruises Maine and resides on a mooring. Once here in my shop it was cycled to 80% DOD then back to 100% SOC twice. It was then equalized at 15.5V for 4 hours, (Lifeline calls this conditioning). The battery then underwent one 20 hour discharge capacity test and was then cycled to 50% SOC and back to 100% SOC, and another 20 hour capacity test was run. The average of the two 20 hour capacity tests was used as the baseline Ah capacity. The baseline Ah capacity of this battery was 95.69Ah. Throughout testing the ambient temp of the battery averaged about 75.2F. While not 77F, the 75F temp should not have negatively impacted the testing. All discharging was done at a constant current and at the 20 hour original factory rating not the as tested Ah capacity. The battery is rated at 105Ah so -5.25A was the discharge rate used. The test was set up to try and simulate real world use on cruising boats.
Testing Tools: Charging - BK Precision 60A Variable Power Supply W/Dedicated Voltage Sensing Discharging - Array DC Programmable DC Electronic Load W/Dedicated Voltage Sensing Temperature - Fluke Infrared Data Logging - Bogart Engineering Pentametric Images - iPad Air with intervalometer software taking 1 picture every 2 minutes
2 Minutes - 50% SOC to 100% SOC .4C Charge Test
For the .4C test the timer was reset to 12:00 and an image was snapped using an intervalometer at 2 minute increments. At 2 minutes the voltage at .4C had already risen to 13.6V.
18 Minutes @ .4C Approaching Absorption Voltage
This shot shows the charger almost ready to exit bulk charging and enter absorption charging.
The term "bulk voltage" may sound fancy & technical but there really is no such thing as a "bulk voltage" because bulk is constant current charging. You can refer to a "bulk transition voltage" (also the absorption transition) where the charger ceases being in constant current but once voltage is held steady or becomes "voltage limited" the charger is no longer in BULK it is in constant voltage not constant current....
If you look closely you can see a little red light next to the letters CC. This means constant current or BULK charging.
Bulk charging is the most efficient part of the recharging process with efficiencies ranging close to 100% of energy delivered by the charger being usable and stored. Once the process switches from constant current/bulk to constant voltage/absorption charge efficiency continues dropping. In the high 90's we are converting a lot less of the supplied energy into stored energy.
06-FEB-2016
Bulk & Absorption
If you read the highlighted part of the Lifeline Battery Technical Manual you will see that Lifeline correctly understands the difference between BULK and ABSORPTION charging. Many companies, including Balmar and many others, do not correctly understand using the word "bulk" correctly. When a company tells you that "bulk" is a voltage limited stage of charging this is PURE MARKETING BOVINE DUNG. Simply put bulk=constant current charging not constant voltage.
BULK - Bulk Charging is the constant current stage of charging where the charge source is limited only by what it can deliver in current. Bulk charging is not a voltage limited stage of charging despite many companies bastardizing the term bulk for apparent marketing purposes.
ABSORPTION - Absorption, float and equalization are all examples of constant voltage charging stages. Absorption or constant voltage is where the charge source holds voltage steady, hence the term "constant voltage". Once voltage is held steady, or it becomes voltage limited, current begins to decline and the charge efficiency worsens. Float charging is a further reduction in the constant voltage limit and an equalization voltage would be a further increase in the constant voltage limit of charging.
The charging devices we use on boats are all considered CC > CV charge sources, or constant current then to constant voltage. Simple stuff really. Please understand that BULK is not a voltage limited stage of charging, despite the marketing guru's vastly missing the mark on this one...
Kudo's to the guys at Lifeline Battery for properly understanding the difference between BULK and ABSORPTION. Shame on companies like Balmar for grossly misleading the consumer.. Words mean certain things and when we blur the definitions to sell $hit, it CONFUSES PEOPLE. (grin)
Let's take a look at a Balmar regulator and use their terminology then a more accurate terminology:
Balmar: Bulk, Bulk Voltage, Absorption Voltage, Float Voltage
What these really are: CC, CV, CV, CV
What it should read: Bulk/CC, Pre-Absorption/CV, Absorption/CV, Float/CV
Please remember that bulk is not a voltage limited stage of charging it is constant current.
20 Minutes @ .4C Absorption Voltage Attained
Based on this image, and the data logger, I know the battery attained 14.4V at around 19 minutes. Here at 20 minutes, with the voltage now held steady at 14.4V (green constant voltage light on) we can see that the charge current has already dropped from 42A to 41.5A or a .5A reduction in accepted charge current into the battery.
If we assume that bulk was 100% efficient, and we will for round numbers, the energy returned to the battery at .4C during bulk charging looks like this:
42A X .32 Hours = 13.44 Ah
If we know the battery had 47.15 Ah left in it, at 49.3% SOC then:
47.15Ah + 13.44Ah = 60.59 Ah stored in the battery
60.59 Ah as a % of 95.69 Ah (tested capacity) = 63.3% SOC
If you're paying attention this battery, when charged at .4C from 49.3% SOC, stayed in BULK/CC for 19 minutes and entered ABSORPTION/CV charging, where current begins declining, at 63.3% SOC.
This clearly shows how charge current affects the SOC transition point from bulk to absorption charging.
1 Hour - .4C Recharge
By 1 hour in our 42A / .4C charge current has already declined to 19.5A..
2 Hours -.4C Recharge
By two hours we are down to just 7.3A...
3 Hours - .4C Recharge
Here we are at 3 hours and current is now down to 2.8A.. That last few % takes the longest!
4 Hours - .4C Recharge
By 4 hours in we were down to 1.1A...
100% SOC - .4C Recharge
Here we are finally at 100% SOC. 100% SOC was deemed as 0.525A flowing into the battery at 14.4V per the Lifeline Battery Technical Manual.
At a .4C charge rate it took this fairly healthy, though not perfect, group 31 battery 5:30 to reach 100% SOC from 49.3% SOC.
2 Minutes - .2C Recharge
Beginning of .2C Recharge Test:
For this test 12.100V was also used as the cut off voltage after a full 100% recharge. The battery spent 32 hours of float at 13.4V and then had a 24 hour resting period. The battery delivered -48.33Ah or just about where it had on the previous test which ended at -48.54Ah.
As we can see in this image at 2 minutes the .2C charge rate only has the battery to 13.1V vs. 13.6V at a .4C charge rate. The voltage is climbing slower in bulk at .2C than it did at .4C.
1 Hour - .2C Recharge
At 1 hour the battery voltage has only risen to 13.8V at a .2C charge rate. The .4C charge rate had attained 14.4V at 19 minutes.
If this was your alternator it had better be robust enough to deliver its full output for at least 1 hour straight. In this case, as you see next, 1:16 minutes before it starts to catch a break. A charge rate of .2C on a 450Ah bank, a pretty typical bank on a coastal cruiser these days, is an alternator that can deliver 90A continuously even when hot.
At 1:16 the battery finally attained 14.4V and the current had begun dropping.
If we assume that bulk was 100% efficient, and we will for round numbers, the energy returned to the battery at .2C during bulk charging looks like this:
21A X 1.27 Hours = 26.67 Ah
If we know the battery had 47.36 Ah left in it, at 49.5% SOC then:
47.36Ah + 26.67 Ah = 74.03 Ah stored in the battery
74.03 Ah as a % of 95.69 Ah (tested capacity) = 77.4% SOC
This battery, when charged at .2C from 49.5% SOC, stayed in BULK/CC for 1:16 minutes and entered ABSORPTION/CV charging, where current begins declining, at 77.4% SOC.
Once again this clearly shows how charge current affects the SOC transition point from bulk to absorption charging. At .4C the battery attained absorption voltage at approx 63.3% SOC and at a .2C charge rate it attained absorption voltage at approx 77.4% SOC.
2 Hours - .2C Recharge
At 2 hours the current is down to 11A..
3 Hours - .2C Recharge
At 3 hours the battery is accepting just 4.2A..
4 Hours - .2C Recharge
At 4 hours the battery is accepting just 1.6A..
Determining 100% SOC
The key piece here is how to determine you are at 100% SOC per the battery manufacturers instructions. Using net return amps, at absorption voltage, (not float voltage) is usually the easiest method when out cruising. Here is a screen capture of the Lifeline Battery Tech Manual. I have highlighted the important part for net return amps determining 100% SOC.
It is saying;
A voltage limit of 14.3V to 14.4V should be used when the battery temperature is at 77F, this battery was at about 75F. When voltage is steady at 14.3V to 14.4V the battery can be deemed 100% full when charging current declines to 0.5% of Ah capacity.
When 14.4V and 0.525A were attained is when I deemed this battery at 100% SOC. Technically the battery was only at 95.69Ah so I should have used 0.48A but close enough for this experiment.
100% SOC - .2C Recharge
Here we are at 100% SOC at the .2C charge rate and it took 5:42 minutes.
Yes it took longer to attain 100% SOC (per Lifeline battery tech manual) but that time was only approx 12 minutes different with double the charge rate. Both charge rates took 5.5+ hours and I have repeated this test with AGM batteries is worse shape that exceeded 7 hours to attain 100% SOC likely due to sulfation.
IMPORTANT: Please understand that you will never likely charge this fast with a typical smart charger. Take for example the .4C charge rate. At 19 minutes it hit absorption voltage. Many so called "smart chargers" begin a timer, I call it an egg timer, once absorption voltage has been attained. If that clock started at 19 minutes, and was 2 hours long, the charger would have dropped to a float voltage of 13.4V at 2:19 minutes! OUCH!!!! Considering it took 5:11 minutes of absorption charging at the .4C charge rate your batteries would likely end up under absorbed, under charged and would not last very long. Once we reduce voltage, eg: dropping to float prematurely, we dramatically EXTEND charging times. In my shop I use adjustable power supplies to avoid dumb smart chargers. With a power supply I can control when the battery changes from absorption to float and not rely on an egg timer.
Is too much current bad for an AGM Battery?
For AGM batteries generally the more current the better. It helps with overall longevity to charge at high rates. Higher charge rates in AGM batteries actually yields longer life not shorter life.
Dave V. the lead engineer at Lifeline battery published a study supporting higher charge rates being good for AGM's.. Odyssey battery, thin plate pure lead AGM batteries, wants to see a minimum of .4C and Lifeline a minimum of .2C as recommended charge current.
This is from the conclusion section of Dave V's study:
"In order to achieve the maximum cycle life from sealed lead acid batteries, (AGM) not only should the DOD be kept as low as possible, but the charge current limit should be as high as possible."
The study then goes on to suggest that a balance needs to be met between equipment and optimal cycle life. Today Dave suggests a minimum charge current of .2C for Lifeline AGM's.
It is a pretty rare boat that can muster a .4C charge rate but some do. On a 450Ah bank that would be an alternator or larger inverter chargers that could sustain 180A when hot.
You as a boat owner will have to decide what it's worth in terms of equipment costs to charge at your AGM's at high charge rates. The eternal question of "Do AGM's charge faster with high charge rates applied?" seems to still be open for debate. This battery only saw an approx 12 minute difference in a 5.5hour charge period but yes it did charge "faster" at .4C than it did at .2C.
It's Important To get Back to 100% SOC!
The importance of getting back to 100% SOC, as often as possible, can not be over emphasized. Here Lifeline Battery is referring to the "walk down" effect of PSOC use (partial state of charge cycling). By not recharging to 100%, as often as possible, your Ah capacity will gradually "walk down" as sulfation becomes permanent and ruins them.
For more information on the effects of PSOC cycling AGM batteries see the May 2015 and August 2015 issues of Practical Sailor Magazine.
SUMMARY: In this test, on this AGM battery, the difference between a .4C and a .2C charge rate, from 50% SOC to 100% SOC, netted a 12 minute total charge time difference.
BEGIN: .2C - 2 Hour Recharge Then Discharge Test
In this second part of the testing I am replicating a few typical scenarios for recharging on a cruising boat. No one wants to run the engine or generator for very long so I wanted to illustrate what kind of energy can be stored in the AGM battery at a 2 hour time interval at a .2C charge rate.
This test started with a discharge from 100% SOC to 50% SOC with the battery delivering 47.85Ah at a 5.25A constant current load. The battery was then recharged for exactly 2 hours at .2C and then immediately discharged back to 50% SOC and the stored energy for that cycle was measured.
The charge rate for this test was 21A and the timer set for 2 hours. If the battery could stay in bulk for two hours our maximum potential energy into the battery would be 42A. Because the battery hit absorption voltage, before hitting the 2 hour mark, we simply can not get 42Ah of energy into the battery...
CHARGING - 2 Hour Charge Test .2C - The Two Minute Mark
At two minutes into the test at 21A the battery terminal voltage is at 13.1V.
MYTH BUSTING: Think about this snap shot if you use or are considering a battery combining relay for charge management and are concerned or have been scared off by one of the many myths surrounding the effective and highly reliable devices. The myth goes something like this: By using a battery combiner on AGM batteries and feeding the alternator or battery chargers charging current directly to the house battery bank first "will leave your start battery under charged". If you are practicing good battery management, and have the minimum suggested charge current for an AGM battery, this is a complete non-issue. In 2 minutes of charging, at 20% of Ah capacity from 50% SOC, the AGM battery voltage is already at the "combine level" for amazingly popular Blue Sea ACR. Battery voltage will rise pretty slowly from here but to get to an ACR's "combine level" is relatively quick and easy, especially if you have your system set up properly. The Echo Charger and Duo Chargers also turn on at similar voltages and those devices require all charge sources to be fed to the house bank.
CHARGING - 2 Hour Charge Test .2C - Two Hour Mark
In this image the charge source is about to turn off when it hits the 2 hour mark. Net accepted current at 14.4V @ 1:58 is down to 11.6A.
DISCHARGING - 2 Hour Charge/Discharge Test .2C - Two Minute Mark
Here the electronic load has turned on and has now begun discharging the battery back down to 50% SOC. I did not pause and let the battery rest between charging & discharging because this is not actually done on cruising boats.
The object with this test is to see how much usable energy we can store in the battery in two hours at a.2C charge rate..
STORED ENERGY - 2 Hour .2C Charge/Discharge Test
After charging the battery from 50% SOC for two hours at 21A we were able to remove 35.28Ah's and bring the battery back down to 50% SOC.
Let's do the math:
Baseline Ah Capacity = 95.69Ah
Discharge to 50% = 47.84Ah (left in the battery after discharge)
2 Hour charge then discharged and counted Ah's delivered back to 50% SOC = 35.28Ah
47.84Ah + 35.28Ah = 83.12Ah of stored energy
83.12 is 86.9% of the baseline Ah capacity of 95.69Ah's
BOTTOM LINE: The battery achieved approx 87% SOC in two hours at a .2C charge rate
******PLEASE CLICK BELOW FOR THE NEXT PAGE******
BEGIN: .4C - 2 Hour Recharge Then Discharge Test
Rather than bore you with multiple images that all look the same I am going to sumarize the remaining three tests with the "stored energy" screen shot.
This test was a .4C charge for two hours and when discharged back to 50% SOC, after the 2 hour charge, the stored energy removed was 44.48Ah. While not a heck of a lot more than .2C it is the attained SOC that really makes .4C different.
Let's do the math:
Baseline Ah Capacity = 95.69Ah
Discharge to 50% = 47.64Ah (left in the battery after discharge)
2 Hour charge then discharged and counted Ah's delivered back to 50% SOC = 44.48Ah
47.64Ah + 44.48Ah = 92.12Ah of stored energy
92.12 is approx 96% of the baseline Ah capacity of 95.69Ah's
BOTTOM LINE: The battery achieved approx 96% SOC in two hours at a .4C charge rate
PERSPECTIVE: Charging to 100% SOC took 5:30 minutes so this means the last 4% of returned energy took 3.5 hours to complete at .4C and the first 46% of capacity could be returned in 2 hours at .4C. The problem still remains that the last 4% is critically important to AGM longevity.
BEGIN: .2C - 1 Hour Recharge Then Discharge
This test was a .2C charge for one hour and then discharged back to 50% SOC, after the 1 hour charge. The stored energy removed was 20.46Ah from a max charge rate of 21A.
CHARGE EFFICIENCY: As I have mentioned before bulk charging, where the charge source provides its full current before the battery reaches the limiting voltage is nearly 100% efficient. Here we have a 1 hour recharge at a charge rate of 21A where the battery was able to store 20.46Ah of that 21A. A 21A charge for 60 minutes is 21Ah's of supplied energy. This means 97.4% of the energy supplied by the charger, or the 21A for exactly 1 hour, was removable as stored energy when we discharged back to 50% SOC. On this 1 hour .2C recharge the battery never attained the absorption voltage of 14.4V and was still in bulk when the charger turned off at the one hour mark.
SCALE IT UP: If we scale this test up, and it should scale well, a .2C charge rate on a 450Ah fairly typical cruising boats house bank would be a continuous 90A for 1 hour before your batteries even hit the absorption voltage set point. Yes, 90A continuously for 1 HOUR!! This is a metric $hit ton of work on a typical 80A - 120A alternator. This is why many a boater has burned up their alternators charging AGM batteries!
MYTH BUSTING: If you believe a battery monitor that counts Ah's, and supplies a fixed charge efficiency number to the returned Ah's (most all of them), can track your batteries accurately when you don't recharge to 100% SOC with each cycle, this myth & lore is blown out of the water right here. In bulk this battery had returned energy efficiency of 97.4% yet the last 4% of returned energy, to 100% SOC, takes 3.5 hours. There is a major difference in charge efficiency throughout the SOC curve. Charge efficiency is not linear throughout the SOC curve, but most all battery monitors are linear in their application of charge efficiency. They simply apply a negative count factor for charge efficiency as the Ah's are returned. For example if we return 10Ah's with a 90% charge efficiency setting the battery monitor will only show that as 9Ah's returned. If we were to stop charging in bulk we really do have closer to 10Ah's returned. Do this a few times........ Ouch! When you cycle more than a few times in the 50% to 90% SOC range there is no way for a typical Ah counter/battery monitor to accurately track your charge efficiency. For more info on this see my article on "Programming a Battery Monitor".
Let's do the math:
Baseline Ah Capacity = 95.69Ah
Discharge to 50% = 47.44Ah (left in the battery after discharge)
1 Hour .2C charge then discharged and counted Ah's delivered back to 50% SOC = 20.46Ah
47.44Ah + 20.46Ah = 67.90Ah of stored energy
67.90Ah is approx 71% of the baseline Ah capacity of 95.69Ah's
BOTTOM LINE: The battery achieved approx 71% SOC in one hour at a .2C charge rate.
PERSPECTIVE: It is pretty clear that a 1 hour charge at .2C is an inadequate charge rate for AGM batteries that are routinely discharged to 50% SOC, unless you really like hearing your motor or generator run.
NOTE: Lifeline Battery recommends a .2C charge rate as the bare minimum for these expensive AGM batteries. Odyssey TPPL AGM batteries are recommended to be charged at a minimum of .4C.
BEGIN: .4C - 1 Hour Recharge Then Discharge
This test was a .4C charge for one hour and then discharged back to 50% SOC, after the 1 hour charge. The stored energy removed was 33.43Ah from a max charge rate of 42A.
SCALE IT UP: If we scale this test up, and it should scale well, a .4C charge rate on a 450Ah fairly typical cruising boats house bank would be a continuous 180A. This battery hit the absorption voltage point at approx 20 minutes when charged at .4C from 50% SOC. With a .4C charge rate your alternator or charger would only be in bulk, or running at its full output, for approx 20 minutes. While this certainly does not make the most efficient use of the alternator, or inverter/chargers, or generators it does charge the batteries to a higher SOC in a short 1 hour run.
Let's do the math:
Baseline Ah Capacity = 95.69Ah
Discharge to 50% = 47.98Ah (left in the battery after discharge)
1 Hour .4C charge then discharged and counted Ah's delivered back to 50% SOC = 33.43Ah
47.98Ah + 33.43Ah = 81.41Ah of stored energy
81.41Ah is approx 85% of the baseline Ah capacity of 95.69Ah's
BOTTOM LINE: The battery achieved approx 85% SOC in one hour at a .4C charge rate.
PERSPECTIVE: While .4C certainly does attain a higher level of SOC in 1 hour, approx 85%SOC, the gain makes ineffective use of a .4C charge source while only utilizing it at 100% for about 20 minutes. Most boaters charging AGM batteries would likely benefit from a compromise charge source current of about .25C to .35C for 1.5 - 2 hours +/- per day. Blended with solar you can get the bank to 85% SOC or so and let the solar take over.
Another View of The Charging Process
Here is another way to look at the charge process. This was a *Lifeline GPL-31XT battery (125Ah rated that was charged at .15C or about 15% of its rated Ah capacity. *NOTE: This was not the battery being tested in this article, and it was used. This image is just for just for illustrative purposes..
BULK: If we start at the top left of the chart we can see that the current held rock steady at 18.75A for *1:42 minutes. This current, 18.75A is .15C or a 15% charging current of a 125Ah battery.
*NOTE: 1:42 minutes of bulk charging (your alternator running at full bore) is more than enough to damage an alternator not otherwise protected for temperature or current limited to protect it. A charge rate of .15C would be an 80-90A alternator on a 400Ah bank, when accounting for the "hot" output, and not all that uncommon. I see lots of burned up alternators when they are under sized for the task.
VOLTAGE RISE: If we look at the left side of the chart we can see the voltage climbing to the absorption set point of 14.4V. It took 1:42 minutes at 18.75A for the battery voltage to attain 14.4V.
1/3 From Left: This is the point where the charge current and voltage flip-flop. Voltage stops climbing and is held steady, and current changes from being steady/constant to declining. Once the BULK/constant current charge has driven the battery voltage to the absorption voltage limit, the voltage is now limited or held steady and the charging current begins to decline.
CHARGE TIME: As current declines, out towards the lower right of the chart, the time it takes to get that last few % in takes significant time. At .15C this slightly used AGM took a bit over 6 hours to reach 100% SOC. I have had sulfated AGM batteries take 7+ hours even at a higher .2C. The health of your AGM battery can impact your time to full.
TESTING SUMMARY:
1- 50% SOC to 100% SOC at .2C = 5:42 - Exited Bulk Charge at 1:16:00 2- 50% SOC to 100% SOC at .4C = 5:30:00 - Exited Bulk Charge at 19 Minutes 3- 50% SOC Charged at .2C For Exactly 1 Hour = 71% SOC - Never Exited Bulk 4- 50% SOC Charged at .4C For Exactly 1 Hour = 85% SOC - Exited Bulk Charge at 19 Minutes 5- 50% SOC Charged at .2C For Exactly 2 Hours = 87% SOC - Exited Bulk Charge at 1:16:00 6- 50% SOC Charged at .4C For Exactly 2 Hours = 96% SOC - Exited Bulk Charge at 19 Minutes
DISCLAIMER: All batteries will test & perform differently based on age, type, chemistry and state of health. This battery and test are only really representative of this battery and test but should give some decent guidance as to what one may expect from a slightly used AGM battery. I purposely did not test a brand new AGM because that is not at all representative of what we as boaters have in use on-board our vessels for more than a short period of time. New batteries will perform differently but our batteries on boats rarely stay new for very long.
Good luck & happy boating!!
MAY-2006
Help Support This Site
Like what you saw or read in this article? Was it helpful? Could the information save you some money? Would you like to see more articles like this?
If so feel free to donate, support the site, and keep it growing. Please DO NOT feel obligated at all. If you like it and want to make a donation, please do. Your donations help keep the content coming and also help keep it FREE.
Click the DONATE button below if you would like to make a donation via PayPal.